CJC Fine Filter
HDU 27/27 M85
HDU 27/27 B M85
Application:
The HDU 27/-series of off-line fine filters are used for the maintenance of fluids for
power transmission, lubrication, cooling, and control systems.
Function:
The filter pump sucks fluid, e.g. from a tank, and presses it through the filter element.
From the centre of the element the fluid flows through the filter base back to the tank.
The pressure drop over the filter - and consequently the contaminant absorption of the filter element - can be monitored on the pressure gauge on the top of the filter
The filter is installed with a suction line connected to the most contaminated point in the system tank - preferably to the bottom drain, if existing.
TECHNICAL DATA
| MODEL | HDU 27/27 M85 | HDU 27/27B M85 |
| Pump yield, std. (ltr/gal/hr) | 90/24 | 360/95 |
| Pump yield, alt. (ltr/gal/hr) | 120/32 | 600/160 |
| Standard Element | HDU 27/27 | B 27/27 |
| Power consumption (kW) | 0.15 | 0.25 |
| Max. pressure drop (bar/psi) | 2.0/30 | 2.0/30 |
| Max. viscosity (cSt) | 100 | 100 |
| Max. fluid temp., approx. (°C/°F) | 85/185 | 85/185 |
| Dirt hold capacity, approx. (ltr/gal) | 4/1.1 | 4/1.1 |
| Operating weight (kg/lb) | 60/132 | 60/132 |
| Max system volume (ltr/gal) | 600/150 | 2400/600 |
APPLICABLE ELEMENTS:
| TYPE | APPLICABLE FOR: |
| HDU | Mineral oils, small flows (small system fluid volumes) |
| B | Mineral oils, large flows (large system fluid volumes) |
| BLA | Water based fluids and emulsions |
| BLDA | Glycol-based flame proof hydraulic fluids |